Akuvox General || A092S A/C Power Wiring Instructions

Akuvox General || A092S A/C Power Wiring Instructions

A092S A/C Power Wiring Instructions

 

Note: A092/ A094 uses A/C Alternating Current with 110/120vac for power. A power cable is not provided and will need to be made or using Romex to run back to the building circuit panel or junction box.

 

  1. Locate the AC Breaker inside the A09x and make sure it is switched OFF (down position).

  2. Insert your 3 prong stripped cable through one of the knockouts in the panel.

  3. Make note of your 3 prong plug cable pinout.

  4. Connect your 3 prong cable “Ground” wire to the A09x chassis using one of the supplied screws and ground locations as seen in the below image example 1.



Example 1

 

  1. Next connect the 3 prong “Neutral” wire to the A09x Circuit Breaker leading to the Converter Terminal labeled “N” as seen in example 1 and 2

Example 2

 

  1. Next connect the 3 prong “Load/ Live” wire to the A09x Circuit Breaker leading to the Converter Terminal labeled “L” as seen in example 1 and 2

  2. Make sure all connections are correct and secured then plug in the 3 prong plug to an outlet and switch on the Circuit Breaker in the A092s.

  3. The A09x will power on with LED’s indicating power.

 

Reference images below: