Akuvox General || Exit Button AC-05 Wiring

Akuvox General || Exit Button AC-05 Wiring

Exit Button AC-05

Connecting to an Akuvox R20A Model door phone as an example.

 

Connect the Orange wire (N/O) from the AC-05 to the 'Door A' input port.

Connect the Yellow wire (COM) from the AC-05 to the 'GND' port.

 

The AC-05 Exit button is powered with a 12-Volt adapter or power supply.

Red wire = Positive (+) from power.

Black wire = Ground (-) from power.

 

 

Log in to the door phone using an internet browser and enter the IP address assigned to your R20A

 

In the R20A device web interface, navigate to 'Intercom' tab on the left.

 

Select the 'Input' tab.

 

 

Checkmark the 'Enabled' box for which input you wish to use.

Under 'Execute Relay' dropdown, select desired relay to be activated.

Click Submit.

    • Related Articles

    • Akuvox General || Maglock & Exit Button Wiring

      Maglock & Exit Button Wiring Using R20K model as an example: Log in to the web interface of the device’s IP address from a web browser. Note: To find the IP address of your device, your computer must be connected to the same network. It is ...
    • Akuvox General || Maglock & Exit Button Wiring for A02S

      Maglock & Exit Button to A02S Wiring Diagram Maglock Wiring: Connect the Positive wire from Maglock to the RELAY_NC port. Connect the Positive wire from Power Supply to the RELAY_COM port. Connect both Negative wires together from Maglock & Power ...
    • Akuvox General || R20A Wiring Diagram Maglock & Exit Button

      Connect 12-Volt Positive from Power Supply to the COM (Common) port on the back of the R20. Connect Positive Wire from the Maglock to the NC (Normally Closed) port. Connect both Negative (Ground) wires together from the Maglock and Power Supply. For ...
    • Akuvox General || A092S A/C Power Wiring Instructions

      A092S A/C Power Wiring Instructions Note: A092/ A094 uses A/C Alternating Current with 110/120vac for power. A power cable is not provided and will need to be made or using Romex to run back to the building circuit panel or junction box. Locate the ...
    • Akuvox General || How to configure exit button with R2X

      Website Configuration Go to Intercom - Input to configure input settings. Input Service: To enable or disable input trigger service. Trigger Option: To choose open circuit trigger or closed circuit trigger. Low means that connection between door ...