Akuvox Hard Reset without Physical Reset Button
____________________________________________
R20 series, R20-2 series, R25A, E12, R27, and R28 Door Phone models can be Factory Reset by Short-circuiting the Input Terminal.
*** Make sure device is Powered Off before you begin the Reset process ***
Example:

(R20A)
With Input A and GND (Ground) terminals Shorted,
Press and Hold the Call Button while Powering On the device.
Continue Pressing Call Button until the light begins Flashing then release.

Button locations for other models:

Related Articles
ENS IPC || IP Camera Reset via Button
ENS-H || IP Camera Reset Button Most ENS-H series IP cameras come with a hard reset button. 1. Disconnect the IP camera from the power source. 2. Press and hold the reset button down then power it back up. 3. Continue to hold the reset button down ...
Emerald IPC || IP Camera Hard Reset
This guide will use EM-IPCP8D3-F28-LH-AI as an example of a IPC that has a physical reset button. IPCs with a reset button will be listed at the bottom as well as a video demonstration. Step 1. Verify that the device is powered up. One of the ways ...
Akuvox General || Maglock & Exit Button Wiring
Maglock & Exit Button Wiring Using R20K model as an example: Log in to the web interface of the device’s IP address from a web browser. Note: To find the IP address of your device, your computer must be connected to the same network. It is ...