Akuvox General || Maglock & Exit Button Wiring

Akuvox General || Maglock & Exit Button Wiring

Maglock & Exit Button Wiring

Using R20K model as an example:




 

Log in to the web interface of the device’s IP address from a web browser.

Note: To find the IP address of your device, your computer must be connected to the same network.

It is recommended that you use the Akuvox IP Scanner tool from the knowledge base website.

(www.knowledge.akuvox.com/docs/akuvox-ip-scanner)


 

Navigate to Intercom > Input


 

Check mark the box to Enable the Input.


 

From the ‘Execute Relay’ option, you may use the drop-down menu to select the desired relay to be triggered.


 

 

    • Related Articles

    • Akuvox General || Maglock & Exit Button Wiring for A02S

      Maglock & Exit Button to A02S Wiring Diagram Maglock Wiring: Connect the Positive wire from Maglock to the RELAY_NC port. Connect the Positive wire from Power Supply to the RELAY_COM port. Connect both Negative wires together from Maglock & Power ...
    • Akuvox General || R20A Wiring Diagram Maglock & Exit Button

      Connect 12-Volt Positive from Power Supply to the COM (Common) port on the back of the R20. Connect Positive Wire from the Maglock to the NC (Normally Closed) port. Connect both Negative (Ground) wires together from the Maglock and Power Supply. For ...
    • Akuvox General || Exit Button AC-05 Wiring

      Exit Button AC-05 Connecting to an Akuvox R20A Model door phone as an example. Connect the Orange wire (N/O) from the AC-05 to the 'Door A' input port. Connect the Yellow wire (COM) from the AC-05 to the 'GND' port. The AC-05 Exit button is powered ...
    • Akuvox General || A092/A094 12-Volt Output Wiring

      A092 / A094 12-Volt Output Wiring For use when installing an Access Control System without utilizing an External Power Supply to provide 12 Volts to devices Using a single Jumper wire; Connect the 12V_OUT to the RELAY_COM port. For Strike Wiring: ...
    • Akuvox General || How to configure exit button with R2X

      Website Configuration Go to Intercom - Input to configure input settings. Input Service: To enable or disable input trigger service. Trigger Option: To choose open circuit trigger or closed circuit trigger. Low means that connection between door ...