Akuvox General || R20A Wiring Diagram Electrified Strike

Connect 12-Volt Positive from Power Supply to the NO (Normally Open) port on the back of the R20.
Connect Positive Wire from the Strike to the COM (Common) port on the back of the R20.
Connect both Negative (Ground) wires together from the Strike and Power Supply.
Related Articles
Akuvox General || Standard Electrified Strike Wiring Diagram
Standard Electrified Strike Wiring Diagram A02/A03 Model relays will be labeled: “RELAY_COM” (Common) “RELAY_NC” (Normally Closed) “RELAY_NO” (Normally Open) Connect the Ground wires together from the Strike & Power Supply using a Wire-nut or B-cap ...
Akuvox Local || Akuvox Door Lock Wiring Diagram
Akuvox Door Lock Wiring Diagram Note: 1. Akuvox integrates circuit protection onto the main board, so you can directly connect Door Strike to Akuvox door phone. 2. When installing a Akuvox door phone at a building without an access control system, ...
Akuvox General || Maglock & Exit Button Wiring for A02S
Maglock & Exit Button to A02S Wiring Diagram Maglock Wiring: Connect the Positive wire from Maglock to the RELAY_NC port. Connect the Positive wire from Power Supply to the RELAY_COM port. Connect both Negative wires together from Maglock & Power ...
Akuvox General || Maglock & Exit Button Wiring
Maglock & Exit Button Wiring Using R20K model as an example: Log in to the web interface of the device’s IP address from a web browser. Note: To find the IP address of your device, your computer must be connected to the same network. It is ...
Akuvox General || A092/A094 12-Volt Output Wiring
A092 / A094 12-Volt Output Wiring For use when installing an Access Control System without utilizing an External Power Supply to provide 12 Volts to devices Using a single Jumper wire; Connect the 12V_OUT to the RELAY_COM port. For Strike Wiring: ...