Using a small piece of wire as a jumper, connect the 12V OUT port to COM1 port
Maglock:
Connect Ground wire to GND_OUT port
Connect Normally Closed wire to NC1 port
**** The 12V Output must be enabled on devices web interface ****
Log in to the web interface of the device’s IP address from a web browser.
Note: To find the IP address of your device, your computer must be connected to the same network.
**** It is recommended that you use the Akuvox IP Scanner tool from the knowledge base website. ****
(www.knowledge.akuvox.com/docs/akuvox-ip-scanner)
Navigate to the Intercom tab.
Select the Advanced tab, then use the drop-down menu for 12V Power Output and choose the desired mode.
Click Submit.
( The 12V output can also be utilized to power other devices such as electrified strikes, request-to-exit sensors, keypads, etc.. )