Akuvox General || Utilizing 12V Output on R27

Akuvox General || Utilizing 12V Output on R27

 

Using a small piece of wire as a jumper, connect the 12V OUT port to COM1 port

 

 

Maglock:

Connect Ground wire to GND_OUT port

Connect Normally Closed wire to NC1 port

 

**** The 12V Output must be enabled on devices web interface ****

 

 

Log in to the web interface of the device’s IP address from a web browser.

 

Note: To find the IP address of your device, your computer must be connected to the same network.

 

**** It is recommended that you use the Akuvox IP Scanner tool from the knowledge base website. ****

 

(www.knowledge.akuvox.com/docs/akuvox-ip-scanner)

 

 

Navigate to the Intercom tab.

 

Select the Advanced tab, then use the drop-down menu for 12V Power Output and choose the desired mode.

 

Click Submit.

 

( The 12V output can also be utilized to power other devices such as electrified strikes, request-to-exit sensors, keypads, etc.. )