Adding a fish eye with multiple panel views. Web_GUI
SIPSFCMS/13-EB V5.7.190 build 220725
Ensure that you have two sections on the live view page (IE mode was enabled)
Two options software and hardware sections.Software solely for a temporary live view. In order to split the fish eye into multiple sections we need to make the change in the hardware section.
After selecting and confirming the display mode and the mounting type, the camera will reboot.
Once it reboots, checking under the hardware section for the camera list, it should populate with multiple camera channels.
Adding it to the recorder
Ensure that you add it using the “manual add” instead of the “quick add”.
It will give you multiple channels to add instead of adding just one.
Depending on the configuration of the Fish eye it will display multiple channels with the same ip address taking up multiple channels on the NVR. In this example, it displays four channels all the same ip address but different channel numbers.