Titanium IPC cameras IP address is 192.168.226.201 by default.
We have two ways to change IP on the camera: we can change IP by the IPtool or log into to the camera or configure a static IP address.
1-Change IP by IPtool:
Open IPtool as administrator select the camera, on the right side we can modify the network Parameter and manually change the IP address. In this example we’ll use 192.168.4.25
Make sure you have the right subnet mask 255.255.255.0 and Gateway 192.168.4.1.
We have to enter the default password on the tool 123456. (Please use Ens12345! If this does not take. Select modify to change to a static IP address.
2-Change IP by web client login (default IP address)
We have to identify the camera with the IPTool and log into the IPC, in case the computer is on a different network we have to add the 192.168.226.100 Network on the local network adapter to allow communication.
Select Network Setting, TCP/IPv4, Advanced and we can add an address that is on the same network as the IPC.
Login to the camera by the web browser Internet Explorer or Edge and select Network settings
Select TCP/IP menu and you will see the default address of 192.168.226.201
You have to change it manually and type the desired IP address ex:192.168.4.25, subnet mask 255.255.255.0 and Gateway 192.168.4.1. ones you finish you can save the changes and the camera it is going to reboot, and you can login with the IP address that you configure before.
In case that you want the camera addressed by DHCP, select Obtain IP address automatically. NOTE: Your camera should use a static IP address. If you do not, the DHCP lease can expire, and the address will change. This will sever the NVR-IPC communication