Akuvox General || How to install a Diode on a Door Strike || Installation
How to install a Diode on a Door Strike:
The majority of Door Strikes will require a diode to be installed when used with an Access Controller. This prevents electrical kickback and damage to your electronic Access Control Terminal. The diode will disapate any electrical charge on its way back towards the access control terminal, preventing an electrical surge from entering the access controller causing possible damage.
Diodes have an Anode (Stripe end) and a Cathode (No Stripe or markings)

Anode (+) Side Cathode (-) Side
Typically you'd only need to install a diode when using a Door Strike that requires power to unlock. The below reference image you can see the position of installation. The Cathode (-) side connects to the Positive side of the lock and the Anode (+) side connects to the Negative side of the lock.

Related Articles
Akuvox General || Installation Quick Start Guides
Akuvox R29 Series Door Phone Quick Guide Akuvox R29 Serises LTE Module Installation Guide Akuvox R29 Serises Rain Cover Installation Guide Akuvox R29C-L Door Phone Cutsheet Akuvox R29 Series Door Phone Cutsheet Akuvox X915 Series Quick Guide Akuvox ...
Akuvox General || How to install Akuvox SR01 to control Electronic Locks || Install
How to install Akuvox SR01 to control Electronic Locks SR01 is a small accessory that improves the security of doors controlled by Akuvox’s door phones. It ensures that the door remains securely locked, even if the door phone is dismounted or ...
Akuvox Local || Akuvox Door Lock Wiring Diagram
Akuvox Door Lock Wiring Diagram Note: 1. Akuvox integrates circuit protection onto the main board, so you can directly connect Door Strike to Akuvox door phone. 2. When installing a Akuvox door phone at a building without an access control system, ...
Akuvox General || Hang Up After Open Door
Akuvox General - Hang Up After Open Door ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Log into Web Portal for the Akuvox Door Phone and navigate to: Intercom ~> Call Feature ~> Hang Up After Open Door Example: (Some models will have a different navigation in ...
Akuvox General || R20A Wiring Diagram Electrified Strike
Connect 12-Volt Positive from Power Supply to the NO (Normally Open) port on the back of the R20. Connect Positive Wire from the Strike to the COM (Common) port on the back of the R20. Connect both Negative (Ground) wires together from the Strike and ...